Gather HBA Information on AIX Virtualization

From one of my logical partitions (lpar) I can see one of my Fibre Channel SCSI I/O Controller Protocol Device in defined state.

Now I can match the “Hardware Location Code” (U9117.MMB.1068B0P-V20-C348-T1) with the Virtual Fibre Channel Host on the VIO.

From VIO as padmin:

Now I have vfchost73 and the VFC client name: fcs15. Lets get more info:

As root on VIO, let’s get a little more info.
@:/home/padmin #lscfg -v -l vfchost73
vfchost73 U9117.MMB.1068B0P-V2-C348 Virtual FC Server Adapter

Hardware Location Code......U9117.MMB.1068B0P-V2-C348
@:/home/padmin #lscfg -v -l fcs15
fcs15 U78C0.001.DBJ3756-P2-C5-T2 8Gb PCI Express Dual Port FC Adapter (df1000f114108a03)

Part Number.................10N9824
Serial Number...............1C046083A9
Manufacturer................001C
EC Level....................D77040
Customer Card ID Number.....577D
FRU Number..................10N9824
Device Specific.(ZM)........3
Network Address.............10000000C9AC5857
ROS Level and ID............02781174
Device Specific.(Z0)........31004549
Device Specific.(Z1)........00000000
Device Specific.(Z2)........00000000
Device Specific.(Z3)........09030909
Device Specific.(Z4)........FF781116
Device Specific.(Z5)........02781174
Device Specific.(Z6)........07731174
Device Specific.(Z7)........0B7C1174
Device Specific.(Z8)........20000000C9AC5857
Device Specific.(Z9)........US1.11X4
Device Specific.(ZA)........U2D1.11X4
Device Specific.(ZB)........U3K1.11X4
Device Specific.(ZC)........000000EF
Hardware Location Code......U78C0.001.DBJ3756-P2-C5-T2

Now, I think I have enough info to send to site support to have them check the cables and blow dust of the HBA.

AIX, Uncategorized

Leave a Reply

Comment
Name*